Internal floor slab stabilised without excavation in Co. Kildare

Challenge

A historic water leak caused the internal floor slab to settle, cracking walls throughout the ground floor while threatening expensive finishes, underfloor heating and the property's habitability.

Solution

Geobear injected geopolymer beneath the slab through 27 precisely positioned points, filling voids, restoring support and protecting underfloor heating without excavation, demolition or removing internal finishes.

1 Day

project completion

27

Injection locations

100mm

Treatment below slab

Background

Geobear was appointed to stabilise a detached two-storey property in Co. Kildare after a historic water leak caused significant settlement of the internal ground floor slab.

The affected slab extended beneath the kitchen, hallway, lounge, sitting room and bedroom. As the slab settled, the internal loadbearing walls constructed upon it also moved, resulting in widespread cracking throughout the property.

The issue had existed for some time, and the homeowner was seeking a permanent, cost-effective solution that could be delivered quickly while avoiding major disruption to the finished home.

Challenge

The conventional solution was to excavate and completely replace the affected floor slab.

This would have required the removal of the staircase, demolition of five internal walls and the stripping out of high-quality floor finishes throughout the ground floor. Following reconstruction, the property would have required extensive reinstatement works and would have been uninhabitable for several weeks.

A further challenge was preserving the property's underfloor heating system during the repair.

Solution

Geobear designed a non-invasive geopolymer injection solution to stabilise the internal floor slab.

A total of 27 injection points were installed on a 1 metre grid pattern across the affected slab. Small access holes were drilled to approximately 100 mm beneath the underside of the slab, allowing expanding geopolymer to be injected into the underlying fill material and any existing voids.

Before work commenced, thermal imaging cameras were used to accurately locate the underfloor heating pipes, ensuring they remained undisturbed throughout the installation.

As the geopolymer expanded, it filled voids, strengthened the supporting ground and restored support beneath the slab, stabilising the structure without excavation or demolition.

The entire project was completed in one day.

Results

The internal floor slab was successfully stabilised while preserving the property's finishes and services.

Compared with complete slab replacement, the Geobear solution delivered significant practical and financial benefits:

  • Completed in one day.
  • 27 injection points installed beneath the slab.
  • Underfloor heating successfully retained and protected.
  • No excavation or demolition required.
  • No removal of the staircase or internal walls.
  • No damage to high-end floor finishes.
  • No spoil removal or heavy construction equipment.
  • Home remained largely unaffected throughout the works.

Let’s talk about your home

Every home is unique. Our experts are ready to listen and provide answers tailored to your specific property and concerns.

Bear pointing Bear pointing